Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 22
4.2
Protected field
The protected field consists of several segments. The front and rear segments (viewed
from the operator's side) can be deactivated. This provides flexibility to adapt to the bend-
ing function:
}
Standard
Full protected field: all segments active
}
Box bending
Reduced protected field: front segments deactivated
}
Bending with back gauge
Reduced protected field: rear segments deactivated
}
Box bending with back gauge
Reduced protected field: front and rear segments deactivated
Bending line
Upper tool
Illuminated target area
Rear segments
Workpiece
Lower tool
Adjustment line
Front segments
Central segments
Fig.: Protected field definitions
The height of the protected field depends on the overrun (see
Overrun [
29]
)
overrun 2 mm
ma
x.
2
0
mm
6
mm
mi
n
.
8
mm
44 mm
1 mm
overrun 14 mm
Fig.: Size of the protected field