Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 70
4.10
Web interface
A web interface is opened in a web browser on the CNC or on a PC; it communicates with
PSENvip via an Ethernet interface. It provides the following options:
}
Operation
Current tool class and the selected protected field mode are displayed
}
Tool change
Tool adjustment during a tool change: The contour of the tool is recorded and assigned to
a tool class. Guides can be used to position the tool correctly.
}
Adjustment
Alignment of receiver to transmitter: The tool is shown with guides and an adjustment
template. It is possible to check that the transmitter and receiver are aligned correctly.
}
Service
System's configuration data, diagnostic data, Firmware status and error messages for
support with troubleshooting. Have this data ready if you require support from Pilz if there
is an error.
}
Settings
Adjusting the settings: the settings can be changed once a password has been entered.
The default user name is "admin" and the default password is "psenvip". Confirm your
entry with
Submit
– A new password can be entered.
– The title of the web interface can be changed
– Access to the Tool Change and Adjustment options can be restricted to certain IP ad-
dresses. A max. of 5 IP addresses can be entered.
– A Firmware update can be performed. Please contact Pilz to perform a Firmware up-
date.
INFORMATION
The
Settings
option can only be selected if the
Operation
option has
already been active.
Help
Help for this web interface is displayed
Layout
Buttons on the left or right-hand border of the web interface are displayed.
The web interface also shows the status of the OSSD signal via a red or green ellipse. If an
error occurs, an error message is shown.
Operation and installation are described in the Commissioning chapter and in the online
help for the web interface.