Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 59
Signal/action
Status
Press
Foot switch
1
KP
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0
System-Init
0
OSSD
1
Mute
0
Muting OSSD
Inactive
Monitoring of braking ramp
Active
Monitoring of pinch point
Active
}
Downward movement, tool centre point reaches muting end point (ME)
Protected field: Interrupted
Dynamic muting: End
Position = Minimum protected field height (including reserve, without advance measuring
field)
Position =
<Configured overrun>
+ 0.4 mm (rounded to mm)
Position value is frozen
Signal/action
Status
Press
Foot switch
1
ME
4 ... 1,6 mm
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0
System-Init
0
OSSD
1 -> 0
Mute
0
Muting OSSD
Start
Monitoring of braking ramp
Active
Monitoring of pinch point
Inactive
}
Downward movement
Protected field: Interrupted
Dynamic muting: Inactive
Position = Frozen value