![Pilz PSENvip E Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/pilz/psenvip-e/psenvip-e_operating-manual_1556621035.webp)
Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 35
4.6.1
Standard interrupted press stroke
The press stroke must be interrupted if
}
an object interrupts the advance measuring field,
}
there is side intervention into the protected field,
}
there is side intervention into a reduced protected field during dynamic muting.
Procedure when advance measuring field is interrupted
Downward movement:
Object interrupts advance meas-
uring field, starts dynamic muting
OSSD signal: 1
Mute signal: becomes 0
LED OSSD: lights
LED Mute: goes out
Control system initiates the stop-
ping of the press, measuring
field was not interrupted in the
expected position (pinch point)
Upper tool continues moving for
the overrun distance, protected
field interrupted. Object is re-
moved. Protected field cleared.
Press stroke can be resumed.