![Pilz PSENvip E Скачать руководство пользователя страница 104](http://html.mh-extra.com/html/pilz/psenvip-e/psenvip-e_operating-manual_1556621104.webp)
Operation
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 104
8.2
Tool change and adjustment after tool change
When a tool is changed, the tool must be repositioned and then an adjustment must be car-
ried out. Both processes are carried out in the web interface. The process is described un-
der "Commissioning":
}
Position tool [
88]
}
Make adjustment during tool change [
92]
In the web interface, when a tool change is requested via the
Tool Change
menu or an ad-
justment is requested after a tool change via the
Adjustment
menu, protected field monit-
oring is interrupted and:
}
The LED on the receiver lights up red.
}
The web interface shows the selected menu. The symbol for the OSSD is red.
}
PSSu K F FAU: The SUP LED goes out. The meaning of the remaining LEDs is de-
scribed in the operating manual PSSu K F FAU B, PSSu K F FAU P.
Once the adjustment (
Adjustment
) or tool change (
Tool Change
) is complete, the system
runs a test. Once the test has been completed successfully, the system starts protected
field monitoring automatically. If an error is detected during the test, protected field monitor-
ing will not be started and an error is reported.