Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 29
4.3
Overrun
The max. overrun is a press brake variable that will depend on the machine type. It is
defined during configuration of the module PSSu K F FAU (see PAS4000 online help for
the PSSu K F FAU) and corresponds to the factory-set default value.
Once the closing movement has stopped, the max. overrun must not be exceeded.
WARNING!
The protected field is reduced when the overrun is too low
A reduced protected field may lead to serious injury and death.
If you require a different overrun path than the factory-set path, then use the
value indicated by the manufacturer on the nameplate of the press brake, or
a higher value. If you enter a lower value for the overrun, the protected field
will also be reduced to an unpermitted level.
The overrun is measured each time the protected field is interrupted at a fast closing speed.
If the overrun is greater than the configured value, the control system PSSu PLC must pre-
vent the continuation of the press stroke at fast closing speed (>10 mm/s) (e.g. interlock,
press stroke only possible in creep speed mode, press restart).