Operation
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 103
NOTICE
Carry out a function test!
When the initial press stroke occurs after the machine is switched on, a
function test must be carried out on the PSENvip, using the test piece.
– Set standard protected field mode.
– Operate the foot switch to initiate the press stroke.
– Carry out a function test as described under
Test the function of the
safeguard [
98]
.
If you have selected a protected field mode with reduced protected field, on each press
stroke you will need to start the reduced protected field via an acknowledgement. Use an
acknowledgement button for the acknowledgement.
WARNING!
Risk of injury due to reduced protected field
Around the bending line there is an increased risk of crushing and trapping
of fingers or hands because
}
with box bending protected field mode, the front segments of the protec-
ted field are blanked,
}
with back gauge protected field mode, the rear segments of the protec-
ted field are blanked,
}
with box bending with back gauge protected field mode, both the front
and rear segments of the protected field are blanked
– Make sure that the workpiece is handled correctly (see
Safety [
12]
).