![Pilz PSENvip E Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/pilz/psenvip-e/psenvip-e_operating-manual_1556621020.webp)
Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 20
4
Function description
4.1
Overview
The detection zone between the transmitter and receiver monitors the immediate danger
zone below the moving upper tool of a press brake. The detection zone moves with the up-
per die, providing mobile safeguarding of the danger zone. The receiver transfers the image
data from the detection zone to the special module PSSu K F FAU. If an object encroaches
into the detection zone, the two outputs on the PSSu K F FAU shut down and the LED on
the receiver goes out. A stop of the press stroke is initiated.
On the productive version, safety functions must be implemented in the PAS4000 user pro-
gram in order to safeguard dynamic muting. Certified Pilz blocks are available for this the
PAS4000 Library.
CNC controller
PSSu system with
PSSu K F FAU
Function blocks
(user program)
Incremental encoder
OSSD status
Image fdata
Receiver
Transmitter PSENvip E
Safety valve
Prefill valve
Foot switch
Emergency switching off
E-STOP contactor
PSENvip R/PSENvip R LR
Fig.: Overview of overall system