Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 27
4.2.1.3
Back gauge protected field mode
With back gauge protected field mode, the rear segments of the protected field are blanked.
This protected field mode is used when the rear back gauge extends into the vicinity of the
bending line. Interruption of the rear segments is to be expected and does not cause the
press stroke to stop.
If the front and middle segments of the protected field are interrupted, the outputs of the
special module PSSu K F FAU shut down.
1
Fig.: Back gauge protected field mode
Legend
}
1: Rear segments of protected field are blanked
The back gauge protected field mode is only active for one press stroke and must be ac-
knowledged by the operator before or during the press stroke.
WARNING!
Risk of injury due to reduced protected field!
Around the bending line there is an increased risk of crushing and trapping
of fingers or hands because the rear segments of the protected field are
blanked.
Make sure that the workpiece is handled correctly (see Chapter "Safety").