Product designation
3-28
PHOENIX CONTACT
6874_en_16
3.3.10
FL IF 2POF SCRJ-D
3.3.10.1
Default upon delivery
When the interface modules are inserted, they are preset with a data transmission rate of
100 Mbps and full duplex mode, and link monitoring is not activated for the fiber optic ports.
3.3.10.2
Functions
–
Line monitoring
According to standard IEEE 802.3, the switch monitors the connected fiber optic cables
for interrupts.
–
Far End Fault Detection indicates that the connection in the direction of the partner is
not OK (the partner does not indicate a link) and therefore at least one fiber within the
fiber optic cable is faulty or has not been assembled correctly.
3.3.10.3
Connecting the SCRJ connectors
NOTE:
If the FL SWITCH MM HS with two FL MXT extension modules is additionally
operated with one FL IF MEM 2TX-D memory module and up to four FL IF POF SCRJ-D
interface modules at the same time, the arrangement according to Section "Arrangement
of the interface modules" on page 2-7 must be observed.
Hot plugging
When inserting and removing interface modules, you do
not
have to switch off the supply
voltage. The interface modules are detected automatically and logged to the network
management.
If the FL IF 2POF SCRJ ... interface is removed and another interface type is inserted in its
place, the ports are set to auto negotiation.
If a fiber optic interface module is inserted in a MMS that has already been parameterized,
the existing configuration remains active.
–
The data transmission rate is set to 100 Mbps
–
The duplex method is set to full duplex
If the module is removed, auto negotiation is enabled.
Ports that are not being used are considered cable interrupts. In addition, a fiber optic path
to a deactivated termination device is also considered a cable interrupt, as the connected
device cannot send a link test pulse because it is switched off.
To prevent dirt from entering the connectors, do not remove the dust protection caps until
just before connecting the connectors. The same applies for the protective caps on the
connectors.