Configuration and diagnostics
6874_en_16
PHOENIX CONTACT
4-85
Description
This object contains the detected PoE class of the connected device to the selected port:
Class 0
0
Class 1
1
Class 2
2
Class 3
3
Class 4
4
Class 5
5
flWorkNetPortPoEOutputCurrent
OID
1.3.6.1.4.1.4346.11.11.4.2.3.1.5
Syntax
Integer (1 - 400)
Access
Read
Description
This object contains the current value of the output current in "mA" of the selected port.
flWorkNetPortPoEOutputVoltage
OID
1.3.6.1.4.1.4346.11.11.4.2.3.1.6
Syntax
Integer32 (45000 - 56000)
Access
Read
Description
Indicates the current output voltage at this port in "mV".
flWorkNetPortPoEFaultStatus
OID
1.3.6.1.4.1.4346.11.11.4.2.3.1.7
Syntax
Integer
Access
Read
Description
Here you can view the current error status of the port:
No error
0
Error in the external PoE supply voltage
1
Temperature too high
2
Current limitation activated
3
Load disconnected
4
The PoE controller does not respond, 48 V supply may be missing
5
No PoE interface module inserted in this slot
6
The switch does not support PoE interface modules
7
No PoE devices connected to this port
8
flWorkNetPortPoEFaultMonitoring
OID
1.3.6.1.4.1.4346.11.11.4.2.3.1.8
Syntax
Integer
Access
Read and write
Description
This object can be used to enable PoE fault monitoring (message via display and alarm
contact) for the relevant port:
Fault monitoring enabled
2
Fault monitoring disabled
1
RSPSupply - 1-888-532-2706 - www.RSPSupply.com