Chapter 5 Trouble shooting and maintenance
5-12
Motor is overheated
Motor runs unevenly
Is the measured load or
the current exceeding
the configured value?
Reduce the load
Increase
ratings of EV and the
motor
Select a different motor
EV fault
Correct bad connection
Clear the debris
Bad connection between EV
and the motor
Is EV
running
in low speed
for a long time
?
Are voltages between
phase
even
?
Is there any debris
preventing cooling
the motor?
YES
YES
YES
YES
YES (measured -3% of output
l
)
NO
NO
NO
Does it occur when
accelerating/
decelerating?
Is the load
freewheeling?
Any vibration or
backlash in the
gears
Is the
acceleration/deceler
ation time correct
for the application?
Increase the acc/dec time
Reduce the load
Increase or ratings for
7300EV and the motor
EV faults
‧
Reduce the freewheeling or
add a flywheel
Improve the mechanical system
EV Faults
YES (measured -3% of rated output voltage)
YES
YES
YES
NO
NO
NO
NO
Small
Large
Are output voltages
between
balanced?
No
Figure5-5 Motor Overload/Overheating Diagnostics
Figure5-6 Oneven Speed Operation Diagnostics