Chapter 3 Environment description and installation
3-27
z
EV-2P2~201-H1FN4(S) (IP65) Connections & EMC Mounting:
z
EV-202~203-H1FN4(S) & EV-401~403-H3FN4(S) (IP65) Connections & EMC Mounting:
200V
400V
NOTE
NOTE:
For IP65 2P2~201 FILTER MODELS, additional items will be find inside the box including: [1] pc of
EMC conformed waterproof (IP65) ferrite core.
"CAUTION: if application require to meet EMC regulation, you MUST first constrain the motor
cables, close the ferrite core onto the motor cable outside the plastic enclosure as stated in the above
diagram. Besides, quadrilateral type ferrite core should close to inverter. Please also note the length of
the Motor cable CANNOT exceed 5M under EMC regulation."
NOTE:
For IP65 202~203 FILTER MODELS, additional items will be find inside the box including: [1] pc
of EMC conformed waterproof (IP65) ferrite core.
"CAUTION: if application require to meet EMC regulation, you MUST first constrain the motor
cables, close the ferrite core onto the motor cable outside the plastic enclosure as stated in the above
diagram. Besides, circular type ferrite core should close to inverter. Please also note the length of the
Motor cable CANNOT exceed 5M under EMC regulation."