PACTware Multi-Input/Output Device Type Manager
2
0
1
8
-0
7
83
10.3.7
Tab "Process Data" for a Counter
This tab contains all settings and parameters for the counter of the channel.
Figure 10.19
Channel "Process Data" tab for the counter
The tab "Process data" contains the following channel information and parameters:
Section "Settings":
■
Target mode:
Mode selection option per channel.
Choose the target mode of the output value for each of the 8 channels.
The following 3 modes are available:
•
Auto:
Automatic.
The measured value of the device is used as output value.
•
Manual
Option to set the output value of the device manually.
•
Out of service
The channel is not in use and the output value is BAD.
Process Data Parameters in the Online Mode
The following parameters contain read-only information displayed in the online mode.
■
Actual mode
Current mode of the channel. The mode can differ from the "Target mode".
Example: A different value or status is selected but the selection is not confirmed yet.
More Information
For more information on the modes of operation, see chapter 8.2.