PACTware Multi-Input/Output Device Type Manager
Setting Up the MIO Device as a Sensor Input
1. Activate the Sensor Input mode with the radio button.
2. Set the required ident number with the radio button.
3. Click on
Next
to adjust the channels as required.
Adjusting the Channels (1): Channel 1 as Binary Input
1. After selecting the sensor input mode,
Next
brings you to the section "Sensor Input
–
Adjust-
ment of Channels 1, 4, 7, and 10".
Figure 10.10
Channel "Basic Setup" tab: Adjust channels of the first measurement loop
2. Set channel 1 to "Binary Input" and select the required sensor-on time from the pull-down
menu.
3. Enable/disable the channels 4, 7, and 10 as required. For enabled channels you can select
a suitable sensor-on time from the corresponding pull-down menu.
4. Click on
Next
. You move to the section "Sensor Input
–
Adjustment of Channels 2, 3, 5, 6, 8,
9, 11, and 12".