Call router configuration task list
387
SmartWare Software Configuration Guide
33 • Call router configuration
Mode:
Context CS
Example:
Configure address completion timeout
node[switch]#address-completion timeout 20
Configures the address completion timeout to 20s. A call with an incomplete called party number is dropped
20 seconds after receiving the last called party address update (overlap dialed digit).
Configure default digit collection timeout and terminating character
You can enter called party routing table entries that specify an incomplete number (extended by the T-indica-
tor; refer to section
“Called party number routing table”
on page 391). When the call router selects such an
entry, the call router waits for additional digits and starts the digit collection timeout. When the digit collec-
tion timeout elapses or when the user enters the terminating character, the call is placed to the destination
specified with the routing table entry.
The digit collection timeout has a default value of 5 seconds, the terminating character is the pound character
(#) by default.
Note
The digit completion timeout is active when the call router waits for
optional digits of a called party number before placing the call to the selected
destination. Contrary to this, the address completion timeout, described
above, waits for mandatory digits.
Procedure:
To configure the digit collection timeout and terminating character
Mode:
Context CS
Step
Command
Purpose
1
node(ctx-cs)[switch]#
address-completion timeout
timeout
Configures the address completion timeout by
specifying the
timeout in seconds. If not config-
ured, the default address completion timeout is
12 seconds.
Step
Command
Purpose
1
node(ctx-cs)[switch]#
digit-collection timeout
timeout
Configures the digit collection timeout by specify-
ing the
timeout in seconds. If not configured, the
default digit collection timeout is 5 seconds.
2
node(ctx-cs)[switch]#
digit-collection terminating-char
char
or
no digit-collection terminating-char
Configures the digit collection terminating charac-
ter by specifying the
char. This can be any charac-
ter out of 0123456789*#. The default
terminating character is the pound (#). You can
also use this command in the no-form to disable
that the user can stop digit collection by a termi-
nating character.
Содержание SmartWare R.3.20
Страница 553: ...553 Appendix A Terms and definitions Chapter contents Introduction 554 SmartWare architecture terms and definitions 554...
Страница 559: ...559 Appendix B Mode summary Chapter contents Introduction 560...
Страница 566: ...566 Appendix D Internetworking terms acronyms Chapter contents Abbreviations 568...
Страница 571: ...571 Appendix E Used IP ports available voice codecs Chapter contents Used IP ports 573 Available voice codecs 574...