![Patton electronics SmartWare R.3.20 Скачать руководство пользователя страница 435](http://html1.mh-extra.com/html/patton-electronics/smartware-r-3-20/smartware-r-3-20_software-configuration-manual_4044387435.webp)
Call router configuration task list
435
SmartWare Software Configuration Guide
33 • Call router configuration
Figure 65. Priority service diagram
By default, the service drops any lower priority calls if a higher priority call fails. However, you have the option
to limit the number of lower priority calls to be dropped if a higher priority call fails. It also blocks new lower
priority calls for a configurable time after a higher priority call failed.
The following procedure demonstrates how to configure a priority service.
Mode
: context cs
Note
Although this service improves the probability that higher priority calls can
be established successfully, there is no guarantee that a higher priority task
can be established successfully at any time.
Step
Command
Purpose
1
node(ctx-cs)[ctx-name]# service
priority <svc-name>
Create a priority service.
2
node(svc-prio)[svc-name]# port
<port-name>
Create a port within the service.
3
node(port)[port-name]# route
dest-….
Define the routing destination for calls received on this
port.
4
(Optional)
node(port)[port-name]# service
priority
Define the priority for calls received through this port.
(The default priority level is 0)
5
node(port)[port-name]# exit
Leave the port configuration mode
6
Repeat steps 2 to 5 for any additional calls you need to
create.
7
(Optional)
node(svc-prio)[svc-name]# max-
calls-to-drop <calls>
Define the maximum number of lower priority calls to be
droppedif a higher priority call fails. (Default is to drop
any lower priority calls.)
8
(Optional)
node(svc-prio)[svc-name]#
quiesce-time <seconds>
Define the time for which lower priority calls are
blocked after a higher priority call failed. (Default is
15 seconds.)
9
(Optional)
node(svc-prio)[svc-name]# retry-
timeout <seconds>
Define the time for which the service waits after a
higher priority call failed until it tries to establish it for a
second time. This allows resources used by dropped
lower priority calls to get available again. (Default is
3 seconds.)
SIP
route 911 dest-service prio.high
route default dest-service prio.low1
high
low1
priority: 2
priority: 0
priority: 0
services priority (prio)
routing table
service hunt-group
FXO If1
FXO If2
low2
Содержание SmartWare R.3.20
Страница 553: ...553 Appendix A Terms and definitions Chapter contents Introduction 554 SmartWare architecture terms and definitions 554...
Страница 559: ...559 Appendix B Mode summary Chapter contents Introduction 560...
Страница 566: ...566 Appendix D Internetworking terms acronyms Chapter contents Abbreviations 568...
Страница 571: ...571 Appendix E Used IP ports available voice codecs Chapter contents Used IP ports 573 Available voice codecs 574...