Serial port configuration task list
174
SmartWare Software Configuration Guide
14 • Serial port configuration
node(pvc)[1]#shutdown
Check the PVC 1 status by using
show running-config
and verify that the entry shutdown occurs in the con-
figuration part responsible for this PVC.
node(pvc)[1]#show running-config
Running configuration:
#----------------------------------------------------------------#
# #
# 2500 #
…
pvc 1
encapsulation rfc1490
bind interface wan router
shutdown
exit
…
Debugging Frame Relay
A set of commands is available to check the status of the Framerelay connections, fragmentation process and
keepalive message exchange. Be aware that some monitors generate a lot of output and can seriously impact
your system performance.This procedure describes how to display the Frame Relay configuration settings for
the serial interface
Mode: Administrator execution
Command
Purpose
[no] debug framerelay
Prints the status of the different monitors (ON or
OFF)
[no] debug framerelay all
Enables/Disables all framerelay debug monitors
[no] debug framerelay error
Enables/Disables monitor which prints only
occurred errors.
[no] debug framerelay lmi
Enables/Disables monitor which prints keepalive
events and messages
[no] debug framerelay management
Enables/Disables monitor which prints management
and configuration events
[no] debug framerelay packets
Enables/Disables monitor which prints dlci, size and
fragmentation status of every incoming and outgo-
ing packet. Be aware that this monitor can seriously
impact your system performance.
Содержание SmartWare R.3.20
Страница 553: ...553 Appendix A Terms and definitions Chapter contents Introduction 554 SmartWare architecture terms and definitions 554...
Страница 559: ...559 Appendix B Mode summary Chapter contents Introduction 560...
Страница 566: ...566 Appendix D Internetworking terms acronyms Chapter contents Abbreviations 568...
Страница 571: ...571 Appendix E Used IP ports available voice codecs Chapter contents Used IP ports 573 Available voice codecs 574...