Serial port configuration task list
171
SmartWare Software Configuration Guide
14 • Serial port configuration
The following example enters the configuration mode for PVC with the assigned DLCI of 1 for Frame Relay
over the serial interface on slot 0 and port 0.
node(cfg)#port serial 0 0
node(prt-ser)[0/0]#framerelay
node(frm-rel)[0/0]#pvc 1
node(pvc)[1]#
Configuring the PVC encapsulation type
You must use the PVC configuration command
encapsulation rfc1490
to set the encapsulation type to com-
ply with the Internet Engineering Task Force (IETF) standard (RFC 1490). Use this keyword when connecting
to another vendor’s equipment across a Frame Relay network.
This procedure describes how to set the encapsulation type to comply with RFC 1490
Mode: Frame Relay
Example:
Configuring the PVC encapsulation type
The following example sets the encapsulation type to comply with RFC 1490 for PVC with the assigned DLCI
of 1 for Frame Relay over the serial interface on slot 0 and port 0.
node(cfg)#port serial 0 0
node(prt-ser)[0/0]#framerelay
node(frm-rel)[0/0]#pvc 1
node(pvc)[1]#encapsulation rfc1490
Binding the Frame Relay PVC to IP interface
A newly created permanent virtual circuit (PVC) for Frame Relay has to be bound to an IP interface for further
use. The logical IP interface has to be already defined and should be named according to the use of the serial
Step
Command
Purpose
1
node(frm-rel)[
slot/port
]#encapsulation rfc1490
Sets RFC1490 PVC compliant encapsulation
Содержание SmartWare R.3.20
Страница 553: ...553 Appendix A Terms and definitions Chapter contents Introduction 554 SmartWare architecture terms and definitions 554...
Страница 559: ...559 Appendix B Mode summary Chapter contents Introduction 560...
Страница 566: ...566 Appendix D Internetworking terms acronyms Chapter contents Abbreviations 568...
Страница 571: ...571 Appendix E Used IP ports available voice codecs Chapter contents Used IP ports 573 Available voice codecs 574...