42
TSM DS 50-003/REV.C/031-300-190-003/04-20-07
DS50 TROUBLE SHOOTING MANUAL LEVEL 3
11. ERROR CODE MESSAGES
Error Code
Error
Cause
Remedy
E14
Load input
voltage is lower
than the
minimum limit
Cable leading from the
central unit to the load cell is
defective or has water in it.
Load cell defective
Analog channel on main
board is defective
If the cable or connector is damaged
replace the cable or the load cell.
Refer to the troubleshooting manual.
Follow the instructions in the
troubleshooting manual and use the
test fixture to clearly identify a load cell
defect. If in doubt contact Hirschmann
service support. In the event of a load
cell defect replace the load cell
referring to the troubleshooting manual
and crane service documentation.
WARNING: Support the hoist drum
while replacing the load cell.
Clearly identify a main board defect by
referring to the troubleshooting manual.
If in doubt contact Hirschmann service
support. Replace main board or
central unit and transfer calibration
data. Afterwards, load test the system.
E15
Communication
lost to angle
sensor
Angle sensor defective or
main board defective
Replace main board and transfer
calibration data. Afterwards, load test
the system.