37
TSM DS 50-003/REV.C/031-300-190-003/04-20-07
DS50 TROUBLE SHOOTING MANUAL LEVEL 3
10. TRANSFERRING EEPROM DATA
6)
Adjust the load offset: Ensure that the hook block is not tight against
the hoist. Press the ENTER key to enter the SETUP menu if required.
Press the UP key until FORCE SENS.ZERO is displayed, then press
the ENTER key. Use the UP or DOWN arrows until zero load is
displayed. Now press the ENTER key to return to the setup menu.
Press the C button to begin moving to the main menu. Use the
UP/DOWN arrows to select YES to save the new values to EEPROM,
then press the ENTER key to return to the main menu.
INIT EEPROM
SETUP
FORCE SENS.ZERO
SETUP
-0.04 TON
FORCE SENS.ZERO
TO EEPROM: NO
SAVE NEW VALUES
TO EEPROM: YES
SAVE NEW VALUES