38
TSM DS 50-003/REV.C/031-300-190-003/04-20-07
DS50 TROUBLE SHOOTING MANUAL LEVEL 3
10. TRANSFERRING EEPROM DATA
7)
Adjust the radius offset: If the crane has no radius offset or a zero
radius offset, skip this step and go to the next step. Press the ENTER
key to enter the SETUP menu if required. Press the UP key until
RADIUS ADJUSTMNT is displayed, then press the ENTER key. Use
the UP or DOWN arrows to display the correct radius adjustment. Now
press the ENTER key to return to the setup menu. Press the C button
to begin moving to the main menu. Use the UP/DOWN arrows to select
YES to save the new values to EEPROM, then press the ENTER key to
return to the main menu.
INIT EEPROM
SETUP
RADIUS ADJUSTMNT
SETUP
.04’
RADIUS ADJUSTMNT
TO EEPROM: NO
SAVE NEW VALUES
TO EEPROM: YES
SAVE NEW VALUES