14
TSM DS 50-003/REV.C/031-300-190-003/04-20-07
DS50 TROUBLE SHOOTING MANUAL LEVEL 3
3.1 THE START UP MENU
Follow the instructions described in section 2.2 to connect the on-line equipment.
Switch the truck power on. A cursor appears on the top left of the hand terminal
display and the red ‘online’ LED lights up. After the DS 50 system has passed the
self test routine, the display shows the start up menu. Refer to drawing 3.1.
The following letters allow the user to select the desired program.
• D = Data output to PC terminal mode. Not used for hand terminal operation.
• H = Data output to hand terminal.
• O = Select the on-line mode. The on-line mode must be selected to adjust
calibration data.
• T = Select the test mode. The test mode allows the user to initialize the EEPROM
prior to a new calibration only and to test the digital inputs such as the function
of the hoist layer switch.
Caution: Do not initialize a calibrated system. Initialization of the EEPROM
results in loss of calibration data and a recalibration becomes
necessary.
Refer to the appropriate section in this manual to distinguish what letter key of the
start up menu to select.
Drawing 3.1.1