32
TSM DS 50-003/REV.C/031-300-190-003/04-20-07
DS50 TROUBLE SHOOTING MANUAL LEVEL 3
10. TRANSFERRING EEPROM DATA
1)
Initialize the EEPROM: Power on the crane. After the unit starts up,
press and hold both the UP and DOWN arrows at once, then press the
ENTER key. This changes to the setup menu, with INIT EEPROM
displayed. Release all 3 keys. Now, press the ENTER key to initialize
the EEPROM. When the menu asks ARE YOUR SURE, use the up or
down arrows to display YES, then press the ENTER key. Press the C
button to return to the main menu.
7.89’ E15 O
.0 DEG
C
X14 X15 X16
Enter key
UP and DOWN arrows
INIT EEPROM
SETUP
ARE U SURE? NO
INIT EEPROM
ARE U SURE? YES
INIT EEPROM