11. ERROR CODE MESSAGES
Error Code
Error
Cause
Remedy
E24
Load input
voltage is
higher than the
maximum limit
Cable leading from the
central unit to the load cell is
defective or has water in it.
Load cell defective
Analog channel on main
board is defective
If the cable or connector is damaged
replace the cable or the load cell.
Refer to the troubleshooting manual.
Follow the instructions in the
troubleshooting manual and use the
test fixture to clearly identify a load cell
defect. If in doubt contact Hirschmann
service support. In the event of a load
cell defect replace the load cell
referring to the troubleshooting manual
and crane service documentation.
WARNING: Support the hoist drum
while replacing the load cell.
Clearly identify a main board defect by
referring to the troubleshooting manual.
If in doubt contact Hirschmann service
support. Replace main board or
central unit and transfer calibration
data. Afterwards, load test the system.
E37
Error in the
EEPROM
Data in the EEPROM is
defective
Initialize the EEPROM, then re-enter
calibration data into it. Turn the power
on and off several times. If the problem
repeats itself, replace the main board.
E57
EEPROM not
initialized
Data in the EEPROM is
defective or lost
Initialize the EEPROM, then re-enter
calibration data into it. Turn the power
on and off several times. If the problem
repeats itself, replace the main board.