28
TSM DS 50-003/REV.C/031-300-190-003/04-20-07
DS50 TROUBLE SHOOTING MANUAL LEVEL 3
8. ADJUSTING RADIUS DISPLAY UNDER LOAD
continuation
Return to section 5 and identify the problem.
Adjust the correction factor to increase or decrease the radius.
Then press the >CR< key to enter the value.
Press the key >K< to return to the start up menu.
Go to section 3.2 and repeat testing the radius under load.
Is the
problem corrected
now?
The End
NO
YES