41
TSM DS 50-003/REV.C/031-300-190-003/04-20-07
DS50 TROUBLE SHOOTING MANUAL LEVEL 3
11. ERROR CODE MESSAGES
Error Code Table for all DS50A2 cranes
Error Code
Error
Cause
Remedy
O
Over load
Cutoff due to over load limit
Reduce load or reduce radius
E05
Length pot
error
The boom length reported from
the length pot is too low:
Clutch between length sensor
pot and gear may be defective
+5V supply to length pot faulty.
Length pot defective
With the boom fully retracted, use the
LCD to adjust the length reading until
this error disappears
Completely replace length pot
assembly and readjust length sensor
pot
Check the +5V supply as described in
the troubleshooting manual. Identify
either a main board defect or length pot
assembly defect.
Replace the length pot. Refer to the
troubleshooting manual for instructions.
E11
Length voltage
is less than
the minimum
limit
The voltage level of the length
pot is too low
Clutch between length sensor
pot and gear may be defective
+5V supply to length pot faulty.
Length pot defective
With the boom fully retracted, adjust
the length pot until this error
disappears, then adjust the length
reading with the internal LCD
adjustment
Completely replace length pot
assembly and readjust length sensor
pot
Check the +5V supply as described in
the troubleshooting manual. Identify
either a main board defect or length pot
assembly defect.
Replace the length pot. Refer to the
troubleshooting manual for instructions.