12. REMOVING TEST AND CALIBRATION EQUIPMENT
Use the following procedure to remove the test equipment after you completed the
adjustments or transfer of data.
•
Unhook any load and move the boom into a safe position. Select a boom position
that allows you to disconnect the calibration equipment safely.
•
Switch off the truck power. Disconnect the interface cable from the DB9 connector.
Store cable and hand terminal in a secured and protected location.
•
Replace the cover on the inner box after checking to ensure that the grounding
cable is connected. Fasten it down with the four screws.
•
Mount the large cover and carefully tighten the four nuts.
•
Re-connect the external cables with the Mil type plugs to the connectors. Refer to the
manual level 1 and level 2 for orientation of those connectors. Be sure the plugs are
tightened to seal against water ingress.
•
Check the system performance by lifting a known test load and a cut off test.
•
If the test fails then you should verify the correct removal of test equipment or
calibration equipment or repeat trouble shooting as described in the Troubleshooting
Manual level 1, 2, and 3.