31
TSM DS 50-003/REV.C/031-300-190-003/04-20-07
DS50 TROUBLE SHOOTING MANUAL LEVEL 3
10. TRANSFERRING EEPROM DATA
In the event of DS 50 main board failure it becomes necessary to install a
Replacement central unit.
Note: All calibration data is stored in the E-EPROM which is installed on the
main board and not removable.
By removing the defective central unit the calibration data becomes
removed. Extract the data prior to disconnecting the defective DS 50
central unit. Truck voltage is required to extract the data.
Newer units also have the calibration data on a plate on the side of the
machine.
C
Angle
Sensor
X14 X15 X16
Drawing 10.1 DS50A2 CPU board