GEA RM1
51
Description of the Gea RM1-PC program
Figure 28 shows the data entry screenshot valid for the generic Dipole-dipole and Polo-
dipolo cases. The dipole-dipole cases Wenner Beta and Dipolo-dipole Wenner Gamma
do not have the input field of the initial value of "b" seen that this parameter has no use
for these two cases, but the operation is similar to the one explained in this paragraph.
The two input fields named "a" initial and "b" initial allow to enter the minimum value to
be applied to the parameters of distances "a" and "b", as they are identified in the
picture/figure.
For the Dipole-dipole Wenner Beta and Dipole-dipole Wenner Gamma methods the two
possible choices that can be applied to the table generation algorithm are: Increment "a"
and Displacement/shifting "O". For the Generic Dipole-dipole and Polo-dipolo methods
the possible choices that can be applied to the table generating algorithm are three:
Increment "a", Increment "b" and Displacement/shifting "O".
The selectable field of Choice 1 allows to define which will be the first parameter that
must change in the construction of the algorithm table. Once you have decided, below the
selectable field an input field is shown where you will be able to enter the increment value
to be applied to the parameter to be modified. The Number of iterations field allows the
operator to define for how many measures the increment value must be applied to the
chosen parameter. Once the parameters have been completed, you must click on the
accept button to be able to accept and to move to the next decision.
Once you have made a choice and pressed the Accept button, some informations on the
table will be shown on the window.
Let’s assume that, in the situation described in Figure 29, as first choice we picked
increment "b", and to have set the increment of "b" to 1.50 meters and to have set 12
Number iterations.
Содержание GEA RM1 1.0
Страница 4: ...4 TEST circuit diagram 67...
Страница 5: ......
Страница 13: ...GEA RM1 9 How to use FIGURE 4 EXAMPLE OF INTEGRAL TABLE FIGURE 5 EXAMPLE WITH SIMPLIFIED VIEW...
Страница 15: ...GEA RM1 11 How to use FIGURE 8 FIGURE 7...
Страница 16: ...12 FIGURE 9 MEASURE WITH INCREASED MN FIGURE 10 REPEAT MEASURE...
Страница 17: ...GEA RM1 13 How to use FIGURE 11 EXECUTE MODIFY REPEAT FIGURE 12 MEASURING EXAMPLE WITH SIGMA 5...
Страница 50: ...46 FIGURE 36 INITIAL PAGE WITH DISCONNECTED SYSTEM FIGURE 37 INITIAL PAGE WITH CONNECTED SYSTEM AND SWITCHED ON...
Страница 56: ...52 FIGURE 42 CONSTRUCTION OF A MANUAL TABLE FIRST PART FIGURE 41 CONSTRUCTION OF A MANUAL TABLE SECOND PART...