50
The program calculates, given the two values, which is the maximum distance AB that
must be reached to completely achieve the measurements of the set session and shows it
on the video.
The manual session with the Generic SEV measurement method only allows the number
of measurements to be set. In this case the program will create a table with the required
number of measures, not calculating the geometric positions of the electrodes but setting
the value to TBD (To Be Defined) and leaving the operator to complete the position
values of the electrodes, if deemed necessary.
Table creation for non-SEV manual measurements
The table of manual measurements implies that the operator must place the electrodes and
connect them to the Gea RM1 system for every single measurement, after which he will
proceed with the execution of the measurement by controlling it from the system.
The tables for manual non-SEV measurements, the Dipole-dipole cases (Wenner Beta,
Wenner Gamma and generic) or Pole-dipole, are constructed by the Gea RM1-PC
program using an algorithm defined by the operator.
F
IGURE
40
-
PAGE CREATION NEW MANUAL TABLE WITH
D
IPOLO
-
DOPOLO
Содержание GEA RM1 1.0
Страница 4: ...4 TEST circuit diagram 67...
Страница 5: ......
Страница 13: ...GEA RM1 9 How to use FIGURE 4 EXAMPLE OF INTEGRAL TABLE FIGURE 5 EXAMPLE WITH SIMPLIFIED VIEW...
Страница 15: ...GEA RM1 11 How to use FIGURE 8 FIGURE 7...
Страница 16: ...12 FIGURE 9 MEASURE WITH INCREASED MN FIGURE 10 REPEAT MEASURE...
Страница 17: ...GEA RM1 13 How to use FIGURE 11 EXECUTE MODIFY REPEAT FIGURE 12 MEASURING EXAMPLE WITH SIGMA 5...
Страница 50: ...46 FIGURE 36 INITIAL PAGE WITH DISCONNECTED SYSTEM FIGURE 37 INITIAL PAGE WITH CONNECTED SYSTEM AND SWITCHED ON...
Страница 56: ...52 FIGURE 42 CONSTRUCTION OF A MANUAL TABLE FIRST PART FIGURE 41 CONSTRUCTION OF A MANUAL TABLE SECOND PART...