Parker EME
Compax3 Accessories
192-120101 N11 C3I11T11 November 2007
265
1*
Strip cable on 140mm
Cut off shield for about 65mm, loosen, fold back over external cover (for about
75mm) and fix with insulating tape.
Fix 2x approx. 30mm shrinking hose (adhesive)
Strip ends of lines for 10mm and fix terminal sleeves 2.5
2*
Strip cable on 160mm
Cut off shield for 140mm, fix rest on a length of 20mm with isolating tape
(width 25mm, length 80mm)
Cut off bck1, bck2, bck3, bck4, bck5 by approx. 15mm (gn/ye about 15mm
longer)
Strip end of lines for about 6mm and fix with cable eyes M6
Please note the two different shield connection elements!
Additional motor cables for the terminal box with similar layout:
MOK62/.. (max. 47.3A) cable chain compatible with 4x10mm
2
+ 2x1mm
2
MOK61/..: (max. 32.3A) cable chain compatible with 4x6mm
2
+ 2x1mm
2
MOK60/.. (max. 13.8A) standard with 6x1,5mm
2
MOK63/.. (max. 13.8A) cable chain compatible with 6x1.5mm
2
MOK64/.. (max. 18.9A) cable chain compatible with 6x2.5mm
2
The designations of the conductors varies according to the cable type:
U U1
sw1 black
V V2
sw2 brown
W W3
sw3 blue
BR+ BR1
sw4
red
BR- BR2
sw5
green
You will find the length code in the
accessories order code
(see page 246).
Designation of the
conductors