Parker EME
Technical data
192-120101 N11 C3I11T11 November 2007
307
EMC limit values Compax3S and Compax3H
EMC interference emission
Limit values according to EN 61 800-3,
Limit value class C3/C4 without additional
mains filter:
Information on C2 limit value classes
(see
page 15)
EMC disturbance immunity
Industrial area limit values in accordance with
EN 61 800-3
Environmnental conditions Compax3MP / Compax3M
General ambient conditions
According to EN 60 721-3-1 to 3-3
Climate (temperature/humidity/barometric
pressure): Class 3K3
Permissible ambient temperature:
Operation
Storage
Transport
0 to +40 C
Class 3K3
–25 to +70 C
–25 to +70 C
Tolerated humidity:
No condensation
Operation
Storage
Transport
<= 85% class 3K3
<= 95%
<= 95%
(Relative humidity)
Elevation of operating site
<=1000m above sea level for 100% load
ratings
<=2000m above sea level for 1% / 100m
power reduction
Please inquire for greater elevations
Sealing
IP20 protection class according to EN 60 529
Mechanic resonances:
Class 2M3, 20m/s
2
;8-200Hz
Cooling Compax3MP / Compax3M
Cooling mode:
Forced air ventilation with fan in the heat
dissipator
EMC limit values Compax3MP/Compax3M
EMC interference emission
Limit values according to EN 61 800-3,
Limit value class C3 with mains filter.
EMC disturbance immunity
Industrial area limit values in accordance with
EN 61 800-3
EC directives and harmonised EC norms
Low voltage directive
2006/95/EC
EN 61800-5-1, Standard for electric power
drives with settable speed; requirements to
electric safety
EN 60664-1, isolation coordinates for electricale
equipment in low-voltage systems
EN 60 204-1, machinery standard partly applied
EC-EMC-directive
2004/108/EC
EN 61 800-3, EMC norm
Product standard for variable speed drives