or
by directly entering under optimization: Analog Input
4.4.8.1
Offset alignment
Performing an offset alignment when working with the ±10V analog interface in the
optimization window under optimization: Analog input Offset [170.4].
Enter the offset value for 0V input voltage.
The currently entered value is shown in the status value "analog input" (optimizing
window at the top right) (unit: 1
≡
10V). Enter this value directly with the same sign
as offset value.
The status value "analogue input" shows the corrected value.
4.4.8.2
Gain alignment
Performing an offset alignment when working with the ±10V analog interface in the
optimization window under optimization: Analog Input: Gain [170.4].
A gain factor of 1 has been entered as default value.
The currently entered value is shown in the status value ”analogue input”
(optimising window at the top right).
The status value "analogue input" shows the corrected value.