![Parker Compax3S025V2 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/parker/compax3s025v2/compax3s025v2_operating-instructions-manual_3903775048.webp)
Compax3
device description
Positioning via digital I/Os
48
192-120101 N11 C3I11T11 November 2007
3.5.4.
Motor / Motor brake C3H
Motor connection clamps
PIN
Designation
M1/U U
(motor)
M2/V V
(motor)
M3/W W
(motor)
PE PE
(motor)
A motor output filter is required for motor cables >50m. Please contact us.
Shielding connection of the motor cable
The motor cable should be fully screened and connected to the Compax3 housing.
The shield of the motor cable must also be connected with the motor housing. The
fixing (via plug or screw in the terminal box) depends on the motor type.
Motor holding brake!
Connect the brake only on motors which have a holding brake!
Otherwise make no brake connections at all.
Requirements cables for motor holding brake
If a motor holding brake is present,
a cable
of the motor holding brake
must be fed on the device side through the toroidal core ferrite provided
as accessory ZBH0x/xx (63
Ω
@1MHz, di=5.1mm), in order to ensure
error-free switching on and off of the motor holding brake.
Connection of motor brake X3
PIN
Designation
1 BR
2 GND
Motor holding brake output
Motor holding brake output
Compax3
Voltage range
21 – 27VDC
Maximum output current (short circuit
proof)
1.6A
Minimum output current
150 mA
Requirements for
Compax3H motor
cable