Setting
up Compax3
Positioning via digital I/Os
130
192-120101 N11 C3I11T11 November 2007
Motor continuous usage
In this chapter you can read about:
Linearized motor characteristic lien for different operating points ...................................................130
This kind of monitoring watches over the continually deliverable torque (continuous
current). This continuous current depends on the velocity and is acquired online
from the linearization of the motor characteristic line.
Linearized motor characteristic lien for different operating points
Nominal point
0
500
1000
1500
2000
2500
3000
0
0.5
1
2
2.5
3
3.5
S1 65°C DT
S3 50% 65°C DT
S3 20% 65°C DT
S1 105°C DT
[A]
[1/min]
2
2
I
0
I
N
n
N
1
I
0
Continual stall current
1: Nominal
point
I
N
:
Nominal current (defined in the MotorManager)
n
N
: Nominal
speed
2: Forbidden
range
For monitoring the continuous usage, the linearized characteristic line between I
0
und I
N
/ n
N
is used as a threshold.