Communication
Positioning via digital I/Os
238
192-120101 N11 C3I11T11 November 2007
5.2.1.
Structure
Layout and configuration of a modem connection ServoManager -
Compax3:
PC
Compax3
ServoManager
Modem 1
konfig
Modem 2
Compax3
X10
SSK31
Phone
konfig
PC
Compax3
ServoManager
konfig
machine
konfig
PC
Hyper-
terminal
Release < R4-5
(115200Baud)
ATE0 cr
ATQ1 cr
1
4
7
2
5
8
3
6
9
Release
> R5-0
Release
> R4-5
< R5-0
konfig
11
konfig
Compax3.ini
Release < R5-0
10
The green part of the drawing shows the proceeding for Compax3 release versions
< R5-0!
The proceeding for Compax3 release versions < R5-0 is described in an
application example (.../modem/C3_Appl_A1016_
language
.pdf on the Compax3
CD).
Connection Compax3 ServoManager <=> Compax3
The Compax3 ServoManager (1) establishes a RS232 connection with modem 1
(PC internal or external).
Modem 1 dials modem 2 via a telephone connection (3).
Modem 2 communicates with Compax3 (6) via RS232.
Configuration
Modem 1 is configured via the Compax3 ServoManager (1)
Modem 2 can be configured via Compax3 (on place), triggered by putting
SSK31
(see page 294) on X10. For this, the device must be configured before. This can
be made locally before the system / machine is delivered with the aid of the
Compax3 ServoManager (8).
The transmission was tested with a TD33 modem made by "
Westermo