Compax3
device description
Positioning via digital I/Os
28
192-120101 N11 C3I11T11 November 2007
3.3.5.
C3Sxxx V2
In this chapter you can read about:
Main voltage supply C3S connector X1.............................................................................................28
Braking resistor / high voltage DC C3S connector X2 .......................................................................29
3.3.5.1
Main voltage supply C3S connector X1
In this chapter you can read about:
Power supply plug X1 for 1 AC 230VAC/240VAC devices................................................................28
Power supply plug X1 for 3AC 230VAC/240VAC devices.................................................................29
By cyclically switching on and off the power voltage, the input current
limitation can be overloaded, which will cause a device error.
Therefore please wait at least 2 minutes after switching off before you switch
the device on again!
Power supply plug X1 for 1 AC 230VAC/240VAC devices
PIN
Designation
1 L
2 N
3 PE
Mains connection Compax3S0xxV2 1AC
Controller type
S025V2
S063V2
Supply voltage
Single phase 230VAC/240VAC
80-253 VAC/50-60Hz
Input current
6Aeff 13Aeff
Maximum fuse rating per device
(=short circuit rating)
10 A (circuit breaker
K)
16 A (circuit breaker K)
Always switch devices off before wiring them!
Dangerous voltages are still present until 5 minutes after
switching off the power supply!
Device protection