![Parker Compax3S025V2 Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/parker/compax3s025v2/compax3s025v2_operating-instructions-manual_3903775102.webp)
Setting
up Compax3
Positioning via digital I/Os
102
192-120101 N11 C3I11T11 November 2007
Input window:
A positioning data record has the following contents:
address Mode Target
position
Posi-
tion
Accele-
ration
Decele-
ration
(delay)
Repetition
number
Address of the positioning data record. The desired positioning data record is
selected via the inputs I3 to I6 (to I7 without machine home switch). The address is
given by the binary value of the inputs, whereby
I3
≡
2
0
= 1
I4
≡
2
1
= 2
I5
≡
2
2
= 4
I6
≡
2
3
= 8
I7
≡
2
4
= 16
POSA: Absolute positioning. Inappropriate in continuous mode and in operation
without machine zero.
POSR: Relative positioning You can carry out relative positionings in absolute
mode, too.
Target position in the chosen unit
Speed in length unit/s
Acceleration in length unit/s
2
Deceleration in length unit/s
2
Only relevant for
sequential positioning
(see page 97).
Specifies how many times execution of the particular positioning data record is
repeated.
Address:
Mode
Target position
Velocity
Acceleration
Deceleration
Repeat count