[Terminal 3]
[S4556] [S4156] [S4576]
Determine how to use terminal 3.
•
Off:
Not used.
•
Alarm input(TRM3):
Receives alarms. When “Alarm input” is selected, a pull-down menu for “Close”
and “Open” is displayed.
–
Close:
An alarm is detected when the terminal status is changed to “Close”.
–
Open:
An alarm is detected when the terminal status is changed to “Open”.
–
Close(Continue):
An alarm is detected when the terminal status is changed to “Close”. When
“Close” is selected for the terminal status, alarm detection will be performed regularly at a fixed interval
set by “Alarm deactivation time”.
–
Open(Continue):
An alarm is detected when the terminal status is changed to “Open”. When
“Open” is selected for the terminal status, alarm detection will be performed regularly at a fixed interval
set by “Alarm deactivation time”.
•
AUX output:
AUX output will be supplied. The [AUX] buttons will be displayed on the “Live” page.
•
Default:
Off
IMPORTANT
• In order for the EXT I/O terminals to detect alarm inputs when the terminal status is changed from
Open to Close (On) or from Close to Open (Off), about 100 ms or more is needed. Because alarms
cannot be detected for about 5 seconds after a detection is made, alarm inputs received within about 5
seconds after an alarm is detected are not detected.
Note
• AUX is a camera terminal that allows users to operate (Open/Close) arbitrarily from the “Live” page.
For example, an operator can remotely control lights in a place where the camera is installed by
connecting the terminal to the light controller.
• Refer to the Installation Guide for further information about input/output rating of each terminal.