1. Self-Diagnostics Function Table
2WAY SYSTEM
Self-Diagnostics Function Table
1. Self-Diagnostics Function Table
•
The outdoor unit maintenance remote controller can be used to check the alarm display.
The number of times that LED 1 and 2 blink on the outdoor unit control PCB can be used to check the alarm display.
(Refer to “Checking the LED 1 and 2 Alarm Display on the Outdoor Unit Control PCB.”)
Alarm code
E06
E12
E15
E16
E20
E24
E25
E26
E29
F04
F05
F06
F07
F14
F16
F17
F24
H06
H15
H22
H21
H25
H27
L04
L10
L17
F22
H11
H12
(EXL1)
(EXL2)
(EXG2)
(TO)
P04
P05
P14
P16
P17
P22
P29
Outdoor unit failed to receive serial communication signals from indoor unit.
Automatic address setting start is prohibited.
Automatic address setting alarm (too few units)
Automatic address setting alarm (too many units)
No indoor units at automatic address setting.
Outdoor unit failed to receive communications from another outdoor unit.
Outdoor unit address setting failure (duplication)
Mismatch in outdoor unit quantity
Outdoor unit failed to receive communication from another outdoor unit.
Outdoor unit serial communications failure
Compressor 1 discharge temperature sensor trouble
Compressor 2 discharge temperature sensor trouble
Gas temperature sensor trouble at outdoor heat exchanger 1
Liquid temperature sensor trouble at outdoor heat exchanger 1
Outdoor air temperature sensor trouble
SCG temperature sensor trouble
High-pressure sensor trouble
Low-pressure sensor trouble
Compressor 3 discharge temperature sensor trouble
Gas temperature sensor trouble at outdoor heat exchanger 2
Liquid temperature sensor trouble at outdoor heat exchanger 2
F31
Outdoor unit non-volatile memory (EEPROM) trouble
Compressor 1 CT sensor disconnected or short-circuit
Low-pressure trouble
Compressor 1 oil detection sensor (connection) trouble
Constant speed compressor 2 overcurrent alarm
Constant speed compressor 2 lock current alarm
Compressor 2 CT sensor disconnected or short-circuit
Compressor 2 discharge temperature sensor disconnected
Compressor 3 overcurrent alarm
Compressor 3 lock current alarm
Compressor 3 CT sensor disconnected or short-circuit
Compressor 3 discharge temperature sensor disconnected
Compressor 2 lock current alarm
Compressor 3 lock current alarm
HIC trouble alarm
Outdoor unit address duplication
Outdoor unit capacity not set
Outdoor unit model mismatch
4-way valve operation failure.
Compressor 1 discharge temperature trouble
High-pressure switch activated
Reverse phase (or missing phase) detected, capacity mismatch
O
2
sensor is activated.
Compressor 1 overcurrent
Compressor 2 discharge temp trouble
Compressor 3 discharge temp trouble
Fan motor trouble
Inverter compressor missing phase or lock alarm
P18
High load alarm
P20
P03
L18
Compressor thermal protector is activated.(trip only and no alarm)
P02
H31
H28
H23
H13
H08
H03
Compressor 1 current trouble
H01
Compressor 1 discharge temperature sensor disconnected
H05
F23
F08
E30
Communication error between the microcomputers
E31
(DISCH1)
(DISCH2)
(EXG1)
(SCG)
F12
Compressor intake temperature sensor trouble
(SCT)
(HPS)
(LPS)
(DISCH3)
Alarm meaning
SM830205-04_2WAY_VRF_Euro.indb 4
14/12/25 16:58:35
Содержание U-8ME1E81
Страница 8: ...vii MEMO SM830205 04_2WAY_VRF_Euro indb 8 15 01 06 17 34 51 ...
Страница 50: ...2 28 MEMO SM830205 04_2WAY_VRF_Euro indb 28 2015 01 23 11 53 29 ...
Страница 90: ...4 6 MEMO SM830205 04_2WAY_VRF_Euro indb 6 15 01 20 15 31 37 ...
Страница 105: ...201502 SM830205 04_2WAY_VRF_Euro indb 1 15 02 13 17 04 58 ...