![Panasonic S-71WF3E Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/panasonic/s-71wf3e/s-71wf3e_service-manual_1507724046.webp)
46
8.2 S-71WF3E
CN141
DCM (WHT)
CN069 (WHT)
REACTOR
RECTIFICATION
CIRCUIT
NOISE
FILTER
CIRCUIT
FUSE F301
T5.0A L250V
CN067
ACIN (BLK)
TM1
ELECTRONIC
CONTROLLER
(MAIN)
1
3
5
1
6
CN061
T10 (YEL)
1
6
CN060
OPTION (WHT)
1
6
CN601
OPT (RED)
1
4
CN066 (WHT)
HU/HEATER
TO OUTDOOR UNIT
TERMINAL
BOARD
1 2 3
1
2
CN032 (WHT)
FAN DRIVE
1
2
CN073
EXCT (RED)
1
2
1
2
CN104
TA (YEL)
CN102
E1 (RED)
BL
BL
BL
INDOOR AIR TEMP.
SENSOR(TA)
INDOOR HEAT EXCHANGER
TEMP. SENSOR(E1)
INDOOR HEAT EXCHANGER
TEMP. SENSOR(E2)
BL
1
2
CN101
E2/E3 (BLK)
BL
BL
G
E
BR
LB or B
BL
REACTOR
1
1
3
4
7
5
6
BL
W
1
3
5
1
3
5
CN076
NANO (WHT)
CN1
(WHT)
CN2
(WHT)
HIGH VOLTAGE
POWER SUPPLY
NANOE-X
GENERATOR
1
2
W
BL
W
R
W
B
BL
FAN MOTOR
W
Y
B
R
BL
W
Y
B
R
BL
CN045 (BLK)
SHORT/OPEN
1
3
CN309
OP1 (YEL)
1
3
WIRE COLOR
B BLUE
O ORANGE
BR BROWN
R RED
G GREEN
W WHITE
LB LIGHT BLUE Y YELLOW
BL BLACK
P PINK
1
2
TO INTEGRATED
CONTROL SYSTEM
1
2
CN040
OC (BLU)
CN041
RC (BLU)
CN044
EMG (BRN)
1
3
W
P
B
BL
TERMINAL
BOARD
U1 U2 R1 R2
WIRED
REMOTE
CONTROLLER
M
DRAIN PUMP
R
1
CN068
DP (WHT)
B
W
M
3
1
2
1
3
1
2
CN034
FS (WHT)
FLOAT SWITCH
Short circuit
connector
Vertical installation
Horizontal installation
BL
BL
BL
BL
TP6/TP3/TP1
SW001
1 2 3
1
6
CN062 (BLK)
TEST/DISP/CHK
t°
t°
t°