How to make drain pump ineffective and changing
heating intake temperature
Operating the High-spec Wired Remote Controller
(CZ-RTC5B)
20:30 (THU)
After completing the address setting under the Section
“12.1.8. TEST RUN”, carry out the following procedure.
1. Keep pressing the
,
and
buttons
simultaneously for 4 or more seconds.
The “Maintenance func” screen appears on the
LCD display.
20:30 (THU)
2. Press the
or
button to see each menu.
If you wish to see the next screen instantly, press
the
or
button. Select “8. Detailed
settings” on the LCD display and press the
button.
20:30 (THU)
The “Detailed settings” screen appears on the
LCD display.
Select the “Unit no.” by pressing the
or
button for changes.
Detailed settings
Unit no. Code no. Set data
10
Sel. Next
20:30 (THU)
3. Select the “Code no.” by pressing the
or
button.
Change the “Code no.” to “3F” by pressing the
or
button (or keeping it pressed).
Detailed settings
Unit no. Code no. Set data
1-1
0007
Sel. Next
20:30 (THU)
3F
4. Select the “Set data” by pressing the
or
button.
(“0007” or “0000” set at shipment)
Change the Setting Data “0001” by pressing the
or
button. Then press the
button.
5. Select the “Code no.” by pressing the
or
button.
Change the “Code no.” to “06” by pressing the
or
button (or keeping it pressed).
Detailed settings
Unit no. Code no. Set data
1-1
0004
Sel. Next
20:30 (THU)
06
6. Select the “Set data” by pressing the
or
button.
(“0004” set at shipment)
Change the Setting Data “0000” by pressing the
or
button. Then press the
button.
7. Select the “Unit no.” by pressing the
or
button and press the
button.
The “Exit detailed settings and restart?”
(Detailed setting-end) screen appears on the LCD
display.
Select “YES” and press the
button.
Detailed settings
Unit no. Code no. Set data
ALL
Sel. Next
20:30 (THU)
010002
Exit detailed settings
and restart?
NO
YES