416
C
o
nt
rol
w
it
h C
om
m
uni
c
a
tion P
or
t
C
h
ap
te
r 9
Geometry Calculation
Parameter
Read Write Minimum value
Maximum value Details
Max. Radius
GGCnnn:RMAX
Yes
Yes
0
99999999.999
Min. Radius
GGCnnn:RMIN
Yes
Yes
0
99999999.999
Max. and Min. Radius
GGCnnn:RPAIR
Yes
Yes
0
99999999.999
Data 1 = Min.
Data 2 = Max.
Max. Major Axis
GGCnnn:LAMAX
Yes
Yes
0
99999999.999
Min. Major Axis
GGCnnn:LAMIN
Yes
Yes
0
99999999.999
Max. and Min. Major
Axis
GGCnnn:LAPAIR
Yes
Yes
0
99999999.999
Data 1 = Min.
Data 2 = Max.
Max. Minor Axis
GGCnnn:SAMAX
Yes
Yes
0
99999999.999
Min. Minor Axis
GGCnnn:SAMIN
Yes
Yes
0
99999999.999
Max. and Min. Minor
Axis
GGCnnn:SAPAIR
Yes
Yes
0
99999999.999
Data 1 = Min.
Data 2 = Max.
Slice Level
The symbol of “?” shown in parameters is a slice level group (A - Z)
Parameter
Read Write Minimum value Maximum value
Details
Max. Slice Level
BLV:H?
Yes
Yes
0
255
Min. Slice Level
BLV:L?
Yes
Yes
0
255
Max. and Min. Slice
Level
BLV:PAIR?
Yes
Yes
0
255
Data 1 = Min.
Data 2 = Max.
Numerical calculation
The symbol of “nnn” shown in parameters is a numerical calculation number (000 - 999).
Parameter
Read Write Minimum value Maximum value
Details
Max. Judgement
CACnnn:MAX
Yes
Yes
-2147483648
2147483647
Min. Judgement
CACnnn:MIN
Yes
Yes
-2147483648
2147483647
Judge. Max. and Min.
CACnnn:LPAIR
Yes
Yes
-2147483648
2147483647
Data 1 = Min.
Data 2 = Max.
Marker
As the marker position should be read/write with a set of X and Y coordinates, use "%PRP" command or
"%PWP" command.
Coordinate values to be read is in units of 0.5 pixels, and the moving distance to be written is in pixel. It is not
possible to read or write with the values after calibration.
"c" of "MRKcg" in the parameters is camera numbers (0-3), and "g" is marker numbers (0-7).
Parameter
Read
Write
Minimu
m value
Maximu
m value
Details
Central Coordinate
(Read))
MRKcg_CXY
Yes
---
-1600
3199
Data 1 = X coordi. *1)
-1200
2399
Data 2 = Y coordi. *1)
Central Coordinate
Moving Distance (Write)
MRKcg:MOV
E
---
Yes
-4799
4799
Data 1 = Distance X *2)
-3599
3599
Data 2 = Distance Y *2)
*1) The number of digits of the coordinate values of response to the read command is as below.
Example
• Positive value: Max. 6 digits
(Integar portion: Max. 4 digits, Decimal point: 1 digit, Decimal
portion: 1 digit)
4
2
8
.
0
• Negative value: Max. 7 digits
(Sign: 1 digit, Integar portion: Max. 4 digits, Decimal point: 1
digit, Decimal portion: 1 digit)
―
4
2
8
.
0
*2) Specify values with the following number of digits to write the moving distance.
Example
• Positive value: Max. 4 digits (Integar portion: Max. 4 digits)
1
0
• Negative value: Max. 5 digits (Sign: 1 digit, Integar portion:
Max. 4 digits)
―
1
2
0
0
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......