Changing the Coordinate Origin and Unit
(Calibration)
Calibration is the function that changes detected data of checkers from pixel unit into actual measure and
moves coordinate origin to a desired position. Calibration can be set by a camera.
After calibration is set, the data detected by checkers is output in calibrated value. Enter the tolerance in
calibrated value in the checkers which detect position (coordinate) or measurement.
Setting example)
The coordinate origin is set at upper left position of the image as the default.
Initial Condition
After Calibration
Setting example)
Coordinate Axis: Rightward
and upward
Origin: (240, 160)
Calibration:
10mm=200 pixels
(coefficient: 0.05)
If the detected coordinate in initial condition is (480, 320), the value turns to be (12, -8) after calibration.
Setting Calibration
Before setting calibration, capture an object or a scale with assured measurement to measure actual size in
pixel unit.
1.
Select the camera No. to set in “Camera” window.
2.
Select "Calibration".
“Calibration” window is displayed.
3.
Set “Calibration” to “Yes”.
Now you can set all items.
4.
Input the setting values for "Real Length X"
and "Real Length Y".
If standard object is 10-mm square, enter “10”
either for Real Length X and Real Length Y. Enter
Real Length in your desired unit. The unit does
not have to be "mm".
5.
Input the setting values for "Length X in
Pixels" and "Length Y in Pixels".
If X and Y are 200 pixels as the result of
measuring the standard object, enter “200” either
for X and Y. The coefficient converting unit is
displayed.
6.
After setting is completed, press the CANCEL
key.
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......