Write Command
This is a command that changes the setting value of PV500. Writing is available only when being in RUN mode
and displaying RUN menu. For the information of writable data, refer to the next page.
When writing one of data (such as System Register, maximum
value, or minimum value)
Send
% P W
Parameter
=
Data
BCC
CR
Receive
% P W $
Parameter
BCC
CR
Error
(ERROR 1 signal = ON)
% P W !
Error code (3-digit)
BCC
CR
Example:
Writes the value “3.14” in System Register 0.
Send
% P W
S Y S : R E G 0 = 3
.
1 4
BCC
CR
Receive
% P W $ S Y S : R E G 0
BCC
CR
When writing two of data (such as maximum value and
minimum value)
Send
% P W P
Parameter
=
Data 1
,
Data 2
BCC
CR
Receive
% P W P $
Parameter
BCC
CR
Error
(ERROR 1 signal = ON)
% P W P !
Error code (3-digit)
BCC
CR
Example:
Writes a maximum value of “100” and a minimum value of “50” in Numerical Calculation
No.10. CACnnn:LPAIR
Parameter for changing the maximum and minimum values in Numerical Calculation
"CACnnn:LPAIR"
Send
% P W P C A C 0 1 0
:
L
P
A I
R
=
5
0
,
1
0
0
BCC CR
Minimum
Maximum
Receive
% P W P $ C A C 0 1 0
:
L
P
A
I
R
BCC CR
Error codes for Write command
200
Operation is stopped.
251
Although PV500 is operating (RUN), displaying SETUP menu cannot write.
251
Specification of the parameter is wrong. (Undefined parameter is specified.)
252
• The specified parameter does not exist. (e.g. The number of uncreated checker is specified as a
parameter.)
• The specified parameter value is out of the settable range. (e.g. Maximum value of slice level is
being set to over 256.)
• The specified values led to the status of “Maximum value < Minimum value” when entering them.
• (When specifying the moving distance of marker)
A part of the circumscribing rectangle of the marker (the intersection point when Shape is
Cross line) after move was out of the nine screens where checker area is settable.
254
The number of write commands received by PV500 exceeds the receivable number when executing
one inspection.
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......