248
Se
tt
ing I
n
s
p
e
c
tio
n C
on
d
it
ions
C
h
ap
te
r 4
4.12.3 Selecting an Image Output Condition
Inspected images can be saved in the image memory of PV500 and output to the external devices when the
judgement of the judging checker is “NG” during an inspection. Select a judging checker to be a condition to
output images.
This setting is available only when the condition of “Image Output” (or “Save Image Memory”) is set to “NG
judgement”. These conditions can be set from “Input/Output” of “ENVIRONMENT”.
This setting is available only when the condition of "Image Output" is set to "NG Judgement" or "Judge. Per
Cam.". These conditions can be set from “Input/Output” of “ENVIRONMENT”.(Refer to page 284 or page 286.)
How to output inspected images
NG Judgment
Outputs all images of the cameras which set to "Output" when the result of one
judgement expression is NG.
Judge. Per Cam.
(Available from
Ver.2.30)
Outputs only the images of cameras whose results of each specified judgement
expression are NG.
Selecting a Condition Expression of Inspection
Image Output
When Output Condition is “NG Judgment” and Execution Mode is "Execute All"
1.
Select "Condition" in judgement output setting window.
“Condition” setting window is displayed.
2.
Select “Condition” column of Save Img. Memory or Image Output.
Select a judgment type to register.
No]:
Not to output images.
[No Condition]:
Always output images
regardless of inspection
results.
[JRC]:
Use a JRC (Internal) as a
condition to image output.
[JDC]:
Use a JRC (External) as a
condition to image output.
**Select ”No Condition” to temporarily output images regardless of a judgement condition when the image
output condition is set to “NG Judgement” or "Judge. Per Cam." which is on the window of “Input/Output” of
“ENVIRONMENT”.
When the other conditions are selected than “NG Judgement” and "Judge. Per Cam.", the setting of
Judgment window is invalid.
(For the setting of "NG Judgement", refer to page 284.)
3.
Select “Checker No.” column and enter a judgment number.
The status of the image output is displayed in the "Result” column.
"No" indicates that image output is not executed because the condition is not fulfilled.
4.
After setting is completed, press the CANCEL key.
Now you completed registering.
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......