In the case of Execution Mode = Float
The procedure described below is for area setting and other inspection conditions when Execution Mode is set
to “Float”.
Setting an Inspection Area
You cannot set a Mask Area in Connector checker.
1.
Select “Area Setting” in “Connector (Gra. Edg.)” setting window.
2.
Select "Area (Set)".
“Area Setting” window is displayed. In Float mode, two areas (Area 0, Area 1) must be set. Area 0 detects
a tip of pin and Area 1 detects base position of float such as a foot of pin. An area displayed in orange
when selecting the window is Area 0.
3.
Move the Area 0 to inspecting area by operating
the ENTER key and press the ENTER key to fix
the position.
4.
Move the start point of Area 0 and fix it. Then,
move the end point and fix it.
In the lower left on the screen, the coordinates of the
start point and the end point of Area 0, and size and
the number of Gray Edge cells are displayed. Use
them to make setting. (See the right table)
5.
Set the size (W) of Gray Edge cells which detect
edges in width measuring area.
The widths in X and Y directions of a cell are defined
as the figures shown on the right.
6.
Tilt the ENTER key left/right to specify the
number of cells, and press the ENTER key to fix
it.
X
(ENTER key,
left/right)
Y
(ENTER key,
up/down)
ST
X coordinate of
the start point
Y coordinate of
the start point
ED
X coordinate of
the end point
Y coordinate of
the end point
W
Width-X of cell
Width-Y of cell
N
Number of cells
(Max. 100)
7.
Tilt the ENTER key up/down to select Area 1.
In the same steps for setting Area 0, move and set a start point and set an end point.
The relative position of the start point and the end point has no effect on edge detection. Set "Detect
Direction" in “Inspect Condition”.
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......