![Panasonic PV-500 Скачать руководство пользователя страница 376](http://html.mh-extra.com/html/panasonic/pv-500/pv-500_user-manual_271804376.webp)
374
O
pe
ra
tio
n a
n
d D
a
ta
O
ut
put
t
hr
ou
gh I
/O
T
e
rm
ina
ls
C
h
ap
te
r 8
Cause
Error
Code
Solution, etc
During continuous inspection, the signal to execute "Reinspection"
is input or the command is sent.
E0204
You cannot reinspect during
continuous inspection.
Although a command (except PIO) to be activated by checking that
the READY signal is on was requested, it was not accepted more
than one second because the READY signal was off (e.g. Detect
trigger or Continuous inspection start was processing, or setting
data was being saved to the PV).
E0205
When you make Template setting with the following conditions;
• It was executed when SETUP menu was displayed.
E0230
Operate PV500.
It was executed when Detect trigger was processing or
Continuous Inspection was used.
Stop Detect trigger and
Continuous Inspection, and
then execute Template setting.
It was executed during parallel I/O output when setting "Area
Display" to "Yes".
Execute Template setting after
the completion of parallel I/O
output.
While “Area Display” is set to “Yes”, the command for Send 2
(%A) was sent when Send 1 was supposed to.
While “Area Display” is set to “Yes”, the command for Send 1
(%Accc,??) was sent when Send 2 was supposed to.
While "Area Display" is set to "No", the command "%A" was
sent.
Enter a command correctly.
• The specified number of checker or template is not create.
• Other number than 000-999 for checker number, or 00-63
for template was specified.
E0231
Specify a correct checker
number or template number.
• Template cannot be set because no image has been
captured after PV500 started up when you select “Use the
Last Image” for “Template Setting.
E0232
Execute an inspection, or
change the setting to “Capture
New Image” to execute
Template setting.
• No feature on the image of template registration area.
• An error occurs in Position adjustment when you use it.
E0233
Check the captured image.
• Template registration area is outside of the captured image
(image partially captured when executing partial imaging).
Adjust the whole registration
area to be in the range of the
captured image.
When the latest inspection image could not output to Ethernet
interface when "ERR signal ON at Output Error" is set to "Yes";
• Ethernet communication cannot be established (with
connection problems including disconnection).
• Image Receiver is not activated.
E0255
Correctly connect Ethernet.
Activate Image Receiver, and
set it to "CONN: Standby".
Parallel Handshake Timeout occurred.
(No ACKNOWLEDGE signal indicating that the external device has
received data was input to PV500 within the Timeout.)
---
Input ACKNOWLEDGE signal
within Handshake Timeout.
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......