5-71
Troubleshooting
(1) Motor connector is shorted or broken.
(2) Motor is defective.
(3) Inverting unit PCB connector (CN601/604)
is shorted or broken.
(4) Inverting unit PCB is defective.
(5) (FP-D250/D350)
LVPS connector (
CN13
) is shorted or
broken.
(FP-D450/D600)
LVPS connector (
CN13
) is shorted or
broken.
(6) LVPS is defective.
(7) (FP-D250/D350)
CPU PCB connector (
CN8
) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (
CN8
) is shorted or
broken.
(8) CPU PCB is defective.
(1) Motor connector is shorted or broken.
(2) Motor is defective.
(3) Inverting unit PCB connector (CN601/602)
is shorted or broken.
(4) Inverting unit PCB is defective.
(5) (FP-D250/D350)
LVPS connector (
CN13
) is shorted or
broken.
(FP-D450/D600)
LVPS connector (
CN13
) is shorted or
broken.
(6) LVPS is defective.
(7) (FP-D250/D350)
CPU PCB connector (
CN8
) is shorted or
broken.
(FP-D450/D600)
CPU PCB connector (
CN8
) is shorted or
broken.
(8) CPU PCB is defective.
Code No.
Function
Check points
E7-30
E7-31
Inverting unit shift motor
Inverting shift transport motor
Содержание FP-D250
Страница 198: ...4 77 PCB Connector and Signal Information 2 Control Panel PCB A FP D250 D350 Series CN354 CN355 Not used...
Страница 332: ...4 211 PCB Connector and Signal Information 2 Control Panel PCB A FP D450 D600 Series CN354 CN355 Not used...